Scolmore enters the consumer unit market  | Voltimum UK

2022-11-11 02:20:50 By : Mr. Johnson s

Marketed under the name ‘Elucian by Click’, the official launch comes following months of extensive research and consultation with contractors and installers to come up with a range of products that best suits their requirements and that are compliant with all the latest regulations.  The introduction of the comprehensive new range means that wholesalers and installers now have access to a one-stop shop for everything wiring accessories related from one of the industry’s most trusted and reliable brands, and Scolmore has made a significant investment to ensure that stock levels of the new products are high to meet the anticipated demand.

Designed with the installer in mind, Elucian is an extensive range of metal consumer units that will cover a broad range of installations and offers a number of features and benefits that will enhance the products’ convenience, flexibility and safety properties. Mk Rcbo 6a

Scolmore enters the consumer unit market  | Voltimum UK

The consumer unit collection comprises a total of 58 individual lines which fall under five main product groups.

Scolmore has highlighted some of the key features that the company believes will make these units stand out in the marketplace and help installers make an informed choice:

Non-combustible and robust metal housings ensure compliance against the third amendment added to the BS 7671 Wiring regulations in 2015 requiring consumer units and similar switchgear assemblies in domestic premises to have a non-combustible enclosure. 

Each consumer and Mini unit come supplied and pre-fitted with a Mains Switch Tail Clamp for added stress relief to ensure the Mains Tails terminations do not come loose and to help fix the Mains Switch Isolator more securely to prevent any rocking or movement.  The Mains Switch Tail Clamp will accept a maximum of 25mm² double insulated tails. 

The units all come supplied with a wide range of 40mm, 32mm, 25mm and 20mm knockouts making each board universally adaptable for all installation and cable types. The knockout positions and sizes were configured as a direct result of feedback obtained during Scolmore’s extensive engagement with contractors across the UK to investigate the number and types of knockouts required in the most convenient locations for ease of install and best installation practice.

The units also come supplied with rounded rectangular knockouts for easy removal and to provide ample cabling capacity for any installation type. Each knockout will be supplied with a 0.5M grommet strip to allow a smooth entry into the board, protecting cable from any potential sharp edges.

Earth and Neutral Bar Configuration  

Each unit has its own specifically configured Earth and Neutral Bar to allow for best practice installation of each board type, neatness of connections and ease of circuit identification.

Backed off Neutral and Earth Bar Screws - for added convenience and to allow quick and easy termination.

Keyway Din Rail - a fast release Keyway Din Rail allows for ease of installation.

MCB style solid blanks for any unused ways.  These are din rail mountable and can only be removed when the cover is removed, thus providing additional safety. Other types of blanks can easily fall out or become dislodged.

The Elucian Circuit Protection Range comprises Mains Isolator Switches, RCCBs, SPDs, MCBs, RCBOs and blank modules.

2 Pole 100A Mains Isolator Switch - the central switch controlling the supply of mains electricity from the meter to the consumer unit and subsequently throughout the rest of the property. A Mains Isolator Switch is switched on and off manually - it will not perform either action automatically or electronically. When the Mains Isolator Switch is turned to the off position, both the incoming Live and Neutral power will be isolated from the unit, isolating the consumer unit/property from the mains electrical supply. 

Type A 2 Pole 30mA RCCBs (63A, 80A and 100A) - constantly monitor the balance of current in the line (Live) and neutral conductors. If an imbalance between the conductors of more than 30mA occurs the device will disconnect within 40mS.  

When an RCCB trips it is usually to prevent any electric shock or personal injury as electricity is flowing through an unintended path to Earth. The RCCB will detect the imbalance and will then trip and turn off the circuit. If Earth leakage is detected, the RCCB will limit the magnitude and duration of the current to Earth.  

Type 2, 2 Pole 40kA SPD available in 275Uc (V~).  Surge Protection Devices are used to protect the circulatory aspects of the installation from an electrical surge, whether that be man-made or due to natural causes such as lightning strikes not direct to the installation. SPDs are used to protect electronic equipment connected to the installation such as computers, televisions, washing machines and LED lighting.

1 Pole, True 6kA B Curve & C Curve MCB’s (6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A and 63A).  The range of B Curve and C Curve Miniature Circuit Breakers are safety switches that turn themselves off automatically to protect electrical circuits from damage in the event of an overcurrent and/or short circuit.

Compact Type A 1 Pole + Neutral True 6kA B Curve & C Curve 30mA RCBOs (6A, 10A, 16A, 20A, 32A & 40A) complete with 450mm Neutral out tails. The Elucian RCBOs are compact single module devices that allow for additional space above to make it easier to install and terminate outgoing circuits. These devices are Type A rated offering a resilience when DC current is present. They are Single pole devices, isolating the Line (Live) conductor only. They only require a Neutral fly lead connection and accept Line (Live) and Neutral terminations direct into the device.

BS 7671 is proposing a move towards the use of RCBOs for the preferred method of protection. This change should be accepted in March 2022.

A single way Din Rail Blank module - Din Rail Blank modules are installed in consumer units in place of vacant spaces, with future expansion in mind. Din Rail Blank modules provide complete protection against access to any potential live parts in applications where a consumer unit is not fully populated with an even amount of circuit protection. 

If you want to leave your comment, please register or log in.

Product tests and other information of over 20 partners in the industry.

Scolmore enters the consumer unit market  | Voltimum UK